NOTE
This vehicle has a low-voltage protection func-
tion.When the vehicle slows down but the fork
is still able to lift, the vehicle will indicate that
the battery voltage is insufficient and the con-
troller will activate the low-voltage protection
function.The battery now needs to be charged.
The hour meter (2)displays the total run time.
Its display range is from 0.0 to 9999.0 hours
and it records the total time spent on driving
and lifting operations.This is displayed in the
background.
Charging procedure
– Control precautions Check for compliance
with charging requirements.
– Park the truck as specified.
– Unplug the mains plug(1), then plug it into a
suitable power supply.
CAUTION
There is a risk of damage to the equipment.
The charging voltage range is 100-240V. Please do
not exceed this voltage range.
Charging indicator(2)
Charging indicator(2) Description Malfunction analysis
Red light remains lit Charger is charging Normal status
Green light remains lit Battery charging is complete Normal status
Yellow light remains lit Battery fault
Battery voltage is less than13V
or greater than 32.5V
Flashing yellow light Charging equipment fault
Output overcurrent;
output overvoltage;
charging equipment tempera-
ture is too high.
Operation
4
Charging and discharging batteries
48 50028011505 EN - 03/2022 - 06