– Pour gear oil into the grease fitting (1)cor-
rectly to replenish it according to specifica-
tions.
NOTE
Top up every 1,000 operating hours or annual-
ly, whichever occurs first.
Checking the fuses
– Fully lower the mast.
– Press the emergency off switch.
– Remove the front hood.
– Check that all fuses are in working order. If
necessary, replace them with fuses that
match the parameters specified in the table
below.
No.
Checking fuses for the fol-
lowing functions or compo-
nents
Value
1 Traction/lift motor fuse 150A
2 Control system fuses 10A
Maintenance
5
Maintenance work
80 50028011505 EN - 03/2022 - 06