BlueMod+B20/BT2.1
User Guide
Release r03 www.stollmann.de Page 23 of 38
6 Out Of Range Detach
If enabled this feature detaches an active link if a given RSSI value is exceeded.
It can be activated by setting the register S410 to 1, the default setting of S410 is 0.
Enable out of range detach
6.1 RSSI Value (S411)
The register S411 sets the RSSI value for the “out of range detach” feature. If set to -80
the link is detached if the measured RSSI exceeds this value. This value can be
configured by the user according the existing scenario.
The application compares the mean value of the last 3 measured RSSI values to the
value set in S411.
6.2 RSSI Poll Time (S412)
The register S412 sets the poll time in milliseconds for measuring the RSSI value for
the “out of range detach” feature. The default value is 3000, the maximum value is
10000. Changing this register affects the processing time of the “out of range detach”
because the polling interval for RSSI is changed.
Set RSSI poll time to 4 seconds