Stonex S800 GNSS Receiver - User Manual - Ver.1-Rev.0 13
powered on, it can automatically start static data logging with no need to
reset.
6.4 RTK Dynamic Measurement (Radio)
RTK dynamic measurement (base and rover) has radio mode and network
mode, which two differs from each other in their ways of transmitting
differential signal.
6.4.1 Installation of Base
1Set up the tripod in location with known coordinates or unknown
coordinates, level it and attach the receiver on it.
2Set up the receiver according to the chosen data link. If using the
internal radio transmission, attach the internal radio antenna into the UHF
antenna port of receiver; if using external radio transmission, connect the
external radio to 5-pin port with 5-pin cable.
3Power on the receiver and select base mode.
6.4.2 Start of Base
Open SurPad on the handheld to choose communication mode. Click
Device- “Working mode” to choose base mode and configure its start up
mode, parameters, data link and satellite system and other settings.
Base has 2 start up modes.
a. Use Current Coordinates
Base uses approximate WGS-84 coordinates of current location as base
coordinates.
b. Input Base Coordinates
User specified base coordinates: the specified base coordinates cannot be far
away from the precise WGS-84 coordinates of the current location, otherwise
the base cannot work.