Direct current DC
Contact Con-
tact-
mate-
rial
Switc
hing
sys-
tem
Con-
nection
Func
tion
Electrical data Operat-
ing life
Temper-
ature
Designation
Circuit as a changeover
Circuit as an NC contact
Silver
Gold (SPS application)
Quick break switch
Switch
Screw connection;
0,75 - 2,5 mn² AWG 20 … 14
Forced opening
2)
Connecting cable switching power
according to EN 60947-5-1
DC-13
Connecting cable switching power
according to EN 60947-5-1
DC-12
I
th
continuous thermal current
U
i
rated insulation voltage
Mechanical Operating life
Service temperature
51
3)
● ● ● ● 4A
24V
1)
6A
250V
30x10
6
-30°C …
+85°C
52
3)
● ● ● ● ● 6A
10A
-25°C …
+80°C
53
3)
● ● ● ● ● 6A 1x10
6
54 ● ● ● ● ● 1A 6A 30x10
6
-30°C …
+85°C
80 ● ● ● ● ● 1A
110V
1)
10A 400V
10x10
6
-40°C …
+85°C
81 ● ● ● ● ● 1A
90 ● ● ● ● ● 0.5A
90G ● ● ● ● ● 0.5A 0.25A 110V
1)
88 ● ● ● ● ● 1.5A 24V
1)
1,5x10
6
-55°C …
+85°C
1)
Values for resistive load
2)
EN 60947–5–1
3)
Gold contacts for switching power < 24V – 100mA
4.1.5 Contact positions
The required dimensions and weights in kg can be obtained from the respective GTES dimensional drawing.
This can be requested as a separate document from Stromag’s Customer Care department.
16