Do you have a question about the Stryker T2 and is the answer not in the manual?
Brand | Stryker |
---|---|
Model | T2 |
Category | Medical Equipment |
Language | English |
Details dimensions, sizes, and features of nails, screws, and end caps for the T2 Recon Nail system.
Explains the integration, usability, and design of the T2 instrument platform for efficient surgery.
Lists the approved uses for the T2 Recon Nail in treating hip and femur fractures.
Advises on important considerations during use, including MR environment safety.
Identifies patient conditions and risk factors that contraindicate the use of the device.
Describes the use of the X-Ray Recon Template for pre-operative planning and radiographic evaluation.
Details proximal locking using two 6.5mm Lag Screws in the Recon Mode.
Explains proximal locking with a single 5mm Fully Threaded Screw in Antegrade Mode.
Guides on patient setup and fracture manipulation for optimal nail insertion.
Describes the recommended skin incision location and length for surgical access.
Details the specific anatomical location for initiating nail insertion into the femur.
Outlines the process of preparing the medullary canal for nail placement.
Provides guidance on choosing the correct nail diameter and length based on measurements.
Explains how to assemble, configure, and lock the targeting device components.
Describes the steps for advancing the selected nail into the medullary canal.
Details methods for achieving optimal nail seating and positioning within the canal.
Guides on proximal and distal screw placement using the targeting system.
Explains using a device to predetermine optimal lag screw placement.
Describes a method for optimizing proximal targeting accuracy using a solid stepdrill.
Presents an alternative technique for proximal screw insertion using a cannulated stepdrill.
Details the process for guided screw insertion in the Antegrade Femoral Mode.
Explains the technique for inserting distal locking screws without a guide.
Describes the final step of securing the nail with a set screw or end cap.
Outlines the steps and tools required for removing the implanted nail.
Lists available left-sided T2 Recon Nail sizes, diameters, and REF numbers.
Lists available right-sided T2 Recon Nail sizes, diameters, and REF numbers.
Provides catalog numbers for various lengths of 6.5mm lag screws.
Lists catalog numbers for various lengths of 5mm locking screws.
Details available end cap sizes and their REF numbers for length adjustment.
Lists available set screws for securing lag screws in Recon/Antegrade modes.
Lists basic long instruments with REF numbers and descriptions for the system.
Lists specific instruments designed for the T2 Recon nailing system.
Catalog of Bixcut modular reamer heads by diameter and REF number.
Catalog of Bixcut fixed head reamers by diameter and REF number.
Lists optional instruments that can be used with the reaming system.
Details available Bixcut reamer shafts by length and REF number.
Lists accessories required for Bixcut reamer shafts.
Lists empty trays designed for organizing Bixcut reamer components.