EasyManua.ls Logo

Summa SummaSign D1300 - Nvram Failures and Messages; Rs232 Error

Summa SummaSign D1300
151 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Manual SummaSign
Syntax errors occur when an incorrect HPGL command is received by the machine.
The next table gives an overview:
Error Number Meaning
1 Instruction is not recognised.
2 Wrong number of parameters.
3 Parameter is out of range or illegal character.
5 Unknown character set.
7 Buffer overflow for polygons or downloadable characters.
10-18 Problems with Device Control Instruction.
Action:
40.Change the data sent to the machine.
41.Refer to the HPGL supported commands.
42.
43.
NVRAM FAILURES AND MESSAGES
Non fatal errors:
SYSTEM NVRAM HAS BEEN DEFAULTED DUE TO ROM CHANGE,
USER NVRAM HAS BEEN DEFAULTED DUE TO ROM CHANGE
Action:
44.Message appears when rebooting the machine for the first time after an upgrade of the
ROM’s. The configuration of the machine will be defaulted. After answering the
questions on the display, this message should no longer appear when the machine is
switched on.
45.If it does replace PCB.
46.
Fatal errors:
SYSTEM NVRAM CHECKSUM FAILURE - SYSTEM NVRAM HAS BEEN DEFAULTED
TRY TO REBOOT MACHINE,
USER NVRAM CHECKSUM FAILURE,
SYSTEM NVRAM WOULD NOT ACCEPT VALUE WRITTEN TO IT,
USER NVRAM WOULD NOT ACCEPT VALUE WRITTEN TO IT.
Action:
47.The preceding messages warn for a problem with the (NV)RAM. Important information can
be lost, such as calibration, landing pressure.
48.Replace the main PCB.
49.
50.
RS232 ERROR
Cause:
Troubleshooting-Error Codes 5-5

Table of Contents

Related product manuals