EasyManuals Logo

Sun Microsystems Sun SPARC Enterprise M4000 Reference Manual

Sun Microsystems Sun SPARC Enterprise M4000
506 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #189 background imageLoading...
Page #189 background image
setdomainmode(8)
System Administration 177
â–  The settings of the current modes of operation for the specified domain can be
checked by using the showdomainmode(8) command. When you use the
showdomainmode(8) command after the setdomainmode(8) command, it will
display the pending modifications performed by the setdomainmode(8), which
might not yet be effective.
EXAMPLES
EXAMPLE 1 Sets the OpenBoot PROM diagnostic level for domain ID 0 to none.
EXAMPLE 2 Enables the auto boot function for domain ID 0. Automatically answers "y"to
all prompts.
XSCF> setdomainmode -d 0 -m diag=none
Diagnostic Level :min -> none
Secure Mode :on -> -
Autoboot :on -> -
CPU Mode :auto -> -
The specified modes will be changed.
Continue? [y|n]:y
configured.
Diagnostic Level :none
Secure Mode :on (host watchdog: available Break-signal:non-receive)
Autoboot :on (autoboot:on)
CPU Mode :auto
XSCF> setdomainmode -y -d 0 -m autoboot=on
Diagnostic Level :none -> -
Secure Mode :on -> -
Autoboot :off -> on
CPU Mode :auto -> -
The specified modes will be changed.
Continue? [y|n]:y
configured.
Diagnostic Level :none
Secure Mode :on (host watchdog: available Break-signal:non-
receive)
Autoboot :on (autoboot:on)
CPU Mode :auto

Other manuals for Sun Microsystems Sun SPARC Enterprise M4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems Sun SPARC Enterprise M4000 and is the answer not in the manual?

Sun Microsystems Sun SPARC Enterprise M4000 Specifications

General IconGeneral
BrandSun Microsystems
ModelSun SPARC Enterprise M4000
CategoryServer
LanguageEnglish

Related product manuals