28 Function Parameter Table
E500 Series Universal Low-Power Inverter
Parameter
Type
Function
Code
Name
Setting Range and
Description
Minimum
unit
Default
setting
Modifica-
tion limit
parameter group
F4.02
Local response
delay
0 ~ 1000ms 1 5
F4.03
Setting of
communication
auxiliary
function
(1)
LED Units:
Inverter main/slave
setting
0: This inverter is a
slave machine
1: This inverter is a
main machine
LED Tens: Selection
of action after
communication
failure
0: Stop
1: Maintaining
current status
LED Hundreds:
Data return
selection
0: Data normal
return
1: No data return
LED Kilobit:
Reserve
1 0010
F4.04
Communication
overtime
detection time
(1)
0.1 ~ 10.0 Sec 0.1 1.0
F4.05
Linkage setting
ratio
(1)
0.1 ~ 10.0 0.1 1.0
F4.06
-
F4.10
Reserve
PID
F5.00
PID function
selection
0: PID closed
1: PID enabled
1 0
F5.01 PID set channel
0: PID Digital
setting
1: frequency input
channel setting
1 0
F5.02
PID digital
setting
0.0%~100.0% 0.1 0.0
F5.03
PID feed
forward
enabling
Units:
0: Void
1: Feed forward
setting ( frequency
input channel )
1 0
F5.04 Reserve
F5.05
PID feedback
correction
0~2.000 0.001 1.000
F5.06 Ratio grain 0.0~10.0 0.1 1.0
F5.07 Integral time 0.01~10.00 0.01 0.20
F5.08 Derivative time 0.0~10.00 0.01 0.0
HRW Limited
admin@hrw.hk
www.hrw.hk

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sunfar E500-2S0015(B) and is the answer not in the manual?

Sunfar E500-2S0015(B) Specifications

General IconGeneral
BrandSunfar
ModelE500-2S0015(B)
CategoryInverter
LanguageEnglish

Related product manuals