EasyManuals Logo

Sunfar E500-2S0015(B) User Manual

Default Icon
103 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
Function Parameter Table 27
E500 Series Universal Low-Power Inverter
Parameter
Type
Function
Code
Name
Setting Range and
Description
Minimum
unit
Default
setting
Modifica-
tion limit
Multispeed and senior running parameter group
F3.26
Swing frequency
running setting
LED Units:
function setting
0: Swing frequency
function closed
1: Swing frequency
function effective
2: Swing frequency
function
conditionally
effective
LED Tens: Center
frequency setting
0: Digital setting
1: Frequency
channel selection
1 0000
F3.27
Swing frequency
amplitude
0.0~50.0% 0.1 10.0
F3.28
Kick frequency
amplitude
0.0~80.0% 0.1 0
F3.29
Triangular wave
descending time
0.1~300.0 S 0.1 1.0
F3.30
Triangular wave
ascending time
0.1~300.0 S 0.1 1.0
F3.31
Swing frequency
center frequency
setting
0.0~[F0.04] 0.1 0.0
F3.32
-
F3.34
Reserve
parameter group
F4.00
Communication
setting
LED Units: Baud
rate selection
0: Reserve
1: 1200 bps
2: 2400 bps
3: 4800 bps
4: 9600 bps
5: 19200 bps
LED Tens: Data
format selection
0: No check
1:Even parity check
2: Odd parity check
LED Hundreds:
protocol selection
0: SUNFAR
self-defined
protocol
1: MODBUS
communication
protocol
LED Kilobit:
Reserve
1 0114 ×
F4.01 Local address
0 ~ 30 1 1
HRW Limited
admin@hrw.hk
www.hrw.hk

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sunfar E500-2S0015(B) and is the answer not in the manual?

Sunfar E500-2S0015(B) Specifications

General IconGeneral
BrandSunfar
ModelE500-2S0015(B)
CategoryInverter
LanguageEnglish

Related product manuals