User Manual 7 Web Main Interface
Parameter Description
Port Cannot be modified.
Communication Error Tripping
Time
When the communication interruption exceeds a
specified time, it will be considered as a communication
anomaly.
Communication Abnormality
Output
When a communication anomaly occurs, the Data
Logger sends the specified dispatch output value.
Communication Error Auto
Recovery Time
When a communication anomaly occurs, the Data
Logger automatically triggers a self-recovery mechanism
after a specific period of time.
Communication Output
Recovered
After communication is restored, instruct the Data
Logger to send commands to the inverters.
Boot: After communication is restored, the Data
Logger sends a power-on command to the inverters.
No Action: After communication is restored, the
Data Logger does not perform any operations.
step 6 Click Save, and the page will prompt you that the changes will take effect after a restart.
- - End
7.9.9 Third-party Portal
Configure the third-party cloud forwarding service for the Data Logger on this page.
Before enabling this switch, ensure that the device is connected to a secure
network.
step 1 Click System > Transfer Configuration > Third-party Portal to enter the Third-party Portal
page.
step 2 Turn on the switch.
step 3 Click to open the Advanced Settings dialog box.
step 4
Modify the configuration information and click Save.
Set the FTP path and name it as "/FTP server directory".
For example, for the name "/SUNGROW", / is the root directory, and SUNGROW is
the directory where data is stored on the FTP server.
- - End