BREAKDOWN
AND
TROUBLESHOOTING
^
If
the
machine
breaks
down
while
using
the
servo
motor
due
to
an
unforseen
change
in
the
machine,
the
error
indicators
mentioned
below
will
appear
In
the
displayer
of
the
program
unit
or
simple
program
unit
according
to
the
self-checking
function
of
the
machine.
The
machine
will
then
stop
along
with
the
sound
of
a
waming
buzzer.
When
an
error
Indicator
appears,
follow
the
solution
steps
described
below
and
resume
work.
If
the
problem
is
not
solved
after
taking
these
measures,
contact
a
company
branch
office.
EiTor
indicator
Cause
of
breakdown
Troubleshooting
SF22
Er
Safety
switch
error
Check
safety
switch
cable
and
connector
PU26
Er
Trouble
wiUi
program
unit
connection
Check
program
unit
cable
and
connector
PU27
Er
Trouble
with
simple
program
unit
connection
Check
the
simple
program
unit
cable
and
connector
60
Er
This
error
sign
is
seen
when
the
user
connects
the
location
sensor
while
the
power
is
still
on
»Turn
the
power
off
and
on
again
before
using
it
61
Er
This
error
sign
is
seen
when
the
user
Uie
user
removes
the
location
sensor
while
the
power
is
still
on
Turn
the
power
off
and
on
again
before
using
it
126
Er
This
error
sign
is
seen
when
the
motor's
rotor
magnet
and
stator
coil's
electric
current
flow
does
not
match
Check
the
condition
of
the
motor's
127
Er
This
error
sign
appears
when
the
direction
of
encoders
R
S
T
and
the
direction
of
A
B
do
not
match.
Check
the
encoder
cable
and
the
connector
128
Er
When
there
is
no
signal
from
encoders
R
S
T
Check
the
encoder
cable
and
the
connector
129
Er
When
the
motor
is
overloaded
Tum
the
machine
manually
and
check
the
machine
load
130
Er
When
ti
^ere
is
no
signal
from
the
location
sensor
Check
fr
ie
location
sensor
cable
and
connector
131
Er
When
there
is
an
electric
current
o\rerflow
in
ti
ie
motor
and
problems
with
the
connector
Check
the
motor
cable
and
the
connector
132
Er
When
does
not
follow
a
speed
Tum
the
power
off
and
on
again
before
using
it.
133
Er
When
theelectric
current
overflow
of
the
IPM
stops
Tum
the
power
off
and
on
again
before
using
it
135
Er
At
the
time
of
the
brake
which
was
caused
by
with
oven/oltage
input
or
ft
jse
damage
Input
voltage
confirmation
Brake
resistance
and
fuse
confirmation.
Of
shift
use
140
Er
Initial
current
sensing
error
'
»Check
initial
current
sensing-related
voltage
setting
values
200
Er
Excessive
error
of
a
motor
load
factor
Check
motor
load
fe
ctor