R
27
9) Needle and Hook Timing
A. Turn on the power switch.
B. Press N1 and N2 key on the operation panel at the same time.
(Refer to hook test function in 14-3)
C. Take off presser foot, needle plate, auxiliary needle plate, feed dog, and
needle plate spacer.
D. Place auxiliary needle plate to needle plate attachment part of sewing
machine bed.
E. When matched from the upper face of auxiliary needle plate to the
bottom of needle bar with height of timing gauge B by turning
sewing machine pulley and raising the needle bar higher than the
lowest point, check the followings:
· Match the sharp end of hook with center of needle.
· Interval of sharp end of hook and needle is 0~0.05mm.
F. If the above status is not made, adjust location of hook by unscrewing
the hook fixing screw.
After adjusting, fasten the fixing screw.
G. When the needle is at the closest location to the left, if point of hook
matched to the center of needle by turning the sewing machine pulley,
check whether size of point of hook is 0.2~0.5mm from the upper end.
If the size does not meet, adjust height of needle bar.
H. In case that over-lapped section sewing causes needle flow, make
needle support to contact to needle by bending needle support as
shown in the figure (a).
Since then, check whether interval of point of hook and needle is
0~0.05 mm.
I. Pressing PARA/SET key on operation panel, it is converted to
embroidery available status.
In case of using 10mm
1) Move the location of needle to the leftest place.
2) When point of hook matched to the center of needle by turning the
sewing machine pulley, adjust needle position whether distance is
0.2~0.5mm to point of hook from the upper end of needle hole.
3) In case of using ZigZag width 10mm, change needle plate, feed dog,
needle bar stopper for 10mm.
[ Fig. 33 ]
10) Location Adjustment of Hook Holder
Adjust that end of hook holder should come to the location
0~0.05 away from end of A part of internal hook.
Keep end of hook holder never comes out to the right
than end of A part of internal hook.
A. Unscrew the fixing screw and adjust location of
hook fixing .
B. Fasten fixing screw tightly.
[ Note ]
As thickness of needle plate and auxiliary needle plate is
different, must use auxiliary needle plate② for sure.
[ Fig. 32 ]
ZigZag Width 0mm
ZigZag Width Max.
→←
0~0.05mm
0~0.05mm
0~0.05mm
0~0.5mm
0.2~0.5mm
(가)
󳟆

Table of Contents