37
[Fig. 60]
19) Setting the X-Y Origin
[Fig. 59]
X-
Origin Sensor
Bracket
X-Sensor Plate
A. How to set the X-shaft origin
Separate the under feed plate from X-fixing cover and transfer cover.
Move the center of upper feed plate to be located the center in the direction of X shaft.
As seen in the below figure, release the 2 fastening screws ① of X shaft origin sensor bracket
and make the X-sensor plate that is adhered to X-Y transfer devices locate the center of
sensor, then fasten the screws with (+) driver.
B. How to set the Y-shaft origin
Separate the set the Y-shaft origin.
Move the center of upper feed plate to be located the center in the direction of Y shaft.
As seen in the below figure, release the 2 fastening screws ① of Y transfer shaft sensor linking plate
and confirm if the Y-sensor transfer plate and sensor works independently, then the fixing screws ①.
Adjust the Y direction origin with the fixing screws of Y-transfer shaft sensor fixing plate.
Y Limit Sensor
Y Origin Sensor
Fixing Plate of Y
Transfer Shaft Sensor
Y Sensor Transfer Plate
Y Transfer
Shaft Sensor
Linking Plate