9. If using a separate foot pedal to trigger the weld, press the foot pedal to trigger a weld
output from the welder.
10. Inspect the weld and adjust weld parameters accordingly. Keep in mind that the effect that
voltage has on a weld is not linear (i.e. a weld made at 4 volts is not twice as powerful as a
weld made at 2 volts. It is closer to four times more powerful.) The weld time is useful for
fine tuning weld results.
11. Once acceptable weld settings have been established, a pull test can be performed to
establish a statistical tracking value.