Chapter 1: Introduction
Information LED
Status Description
Continuously on and
red
An overheat condition has occurred.
(This may be caused by cable congestion.)
Blinking red (1Hz) Fan failure, check for an inoperative fan.
Blinking red (0.25Hz)
Power failure, check for a non-operational power
supply.
Solid blue
Local UID has been activated. Use this function
to locate the server in a rack mount environment.
Blinking blue
Remote UID is on. This indicator can be
activated using IMPI from a remote location.
Chassis Front
The illustration below shows the features included on the front of the chassis. Externally
accessible hard drive carriers display status lights.
Figure 1-2. Front View
Chassis Front Features
Item Features Description
1 Control Panel Power buttons and status indicators
2 Storage Drives Twelve 3.5" drive bays
3 Optional NVMe
Four bays for optional NVMe drives; see the "Storage Drive" section in Section 3.4
for details
4
Asset/Service
Tag
2
3