SuperServer 6029U-T Series User's Manual
24
Figure 2-4. Extending and Mounting the Outer Rails
Installing the Outer Rails onto the Rack
Each end of the assembled outer rail includes a bracket with hooks and square, spring-loaded

Installing the Outer Rail
1. Press upward on the locking tab at the rear end of the middle rail.
2. Push the middle rail back into the outer rail.
3. Hang the hooks on the front of the outer rail onto the square holes on the front of the
rack. If desired, use screws to secure the outer rails to the rack.
4. 
the rack.
5. Hang the hooks of the rear section of the outer rail onto the square holes on the rear of
the rack. Take care that the proper holes are used so the rails are level. If desired, use
screws to secure the rear of the outer rail to the rear of the rack.
Note:

Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be

can cause the rack to tip over.
21D01
L-min=676.00(26.61")(outer rail)
1
4
3
2
Warning: Do not pick up the server with the front handles. They are designed to pull the
system from a rack only.