97
Chapter 6: Optional Components
CreatingNVMeRAIDCongurations
1. Open Advanced>Intel(R)VirtualRAIDonCPU>AllIntelVMDControllers>
CreateRAIDVolume.
2. Set Name.
3. Set RAIDLevel.
4. If cross-controller RAID is required, select EnableRAIDspannedoverVMD
Controller.
5. Select specic disks for RAID with an [X].
RAID0: Select at least two [2 - 24] disks
RAID1: Select only two disks
RAID5: Select at least three [3 - 24] disks
RAID10: Select only four disks
6. Select Strip Size (Default 64KB).
7. Select CreateVolume.
8. If another RAID is needed, start again at step 1.
Figure6-13.CreatedVolumewithout
enablingRAIDspannedoverVMD
controller
Figure6-14.CreatedVolumewith
enablingRAIDspannedoverVMD
controller