83
Chapter 6: Optional Components
10. If cross-controller RAID is required, select Enable RAID spanned over VMD
Controller .
11.
• RAID0: Select at least two [2 - 24] disks
• RAID1: Select only two disks
• RAID5: Select at least three [3 - 24] disks
• RAID10: Select only four disks
12. Select Strip Size (Default 64KB).
13. Select Create Volume.
14. If another RAID is needed, start again at step 9.
15. Press [F4] to save and reboot.
Related Information Links
[1] https://kb.vmware.com/s/article/2151404
[2] https://docs.vmware.com/en/VMware-vSphere/6.5/com.vmware.vsphere.storage.doc/
GUID-1B56EF97-F60E-4F21-82A7-8F2A7294604D.html
[3] https://docs.vmware.com/en/VMware-vSphere/6.5/com.vmware.vsphere.storage.doc/
GUID-F2E75F67-740B-4406-9F0C-A2D99A698F2A.html
Figure 6-8. Created Volume without
enabling RAID spanned over VMD
controller
Figure 6-9. Created Volume with
enabling RAID spanned over VMD
controller