Chapter 7: Troubleshooting and Support
7.7 CMOS Clear

consists of contact pads to prevent accidentally clearing the contents of CMOS.
To Clear CMOS
1. First power down the system completely.
2. Remove the system to access the motherboard.
3. Remove the onboard battery from the motherboard.
4.       
seconds.
5. Remove the screwdriver or shorting device.
6. Replace the cover, reconnect the power cords and power on the system.
Notes: Clearing CMOS will also clear all passwords.
Do not use the PW_ON connector to clear CMOS.
JBT1 contact pads
7.8 BMC Reset
The BMC can be reset using the UID button.
Reset – Press and hold the button. After six seconds, the LED blinks at 2Hz. The BMC
resets and the reset duration is ~250 ms. Then the BMC starts to boot.

      Note: All BMC settings including username and
password will be removed except the FRU and network settings.

BMC Reset Options
Event UID LED BMC Heartbeat LED
Reset Blue, Blinks at 2Hz Green, solid
Restore
Defaults
Blue, Blinks at 4Hz 󰀨
Update Blue, Blinks at 10Hz

Table of Contents