Function parameter description NICE3000 User Manual
106
First, set F0-01 as 0: the control mode selection is the operating panel command channel.
Set F1-00 as 0 by actual motor types: asynchronous motor. Then set F1-01F1-02F1-03
F1-04F1-05 according to the nameplate parameters of motor.
If the motor can be separated from load, the parameter F1-11 selects 2(motor no-load tuning).
Then press RUN of the operating panel and the motor can automatically run.
The control
automatically counts these parameters as follows: F1-06 (stator resistance), F1-07 (rotor
resistance), F1-08 (leakage inductance), F1-09 (mutual inductance) and F1-10 (no-load
excitation current). The motor tuning is then over. If the system appears over current, please
increase the parameter F1-10, but dont exceed 20%.
If the motor cant be separated from load, the parameter F1-11 se
lects 1(motor with-load
tuning).Then press RUN of the operating panel and the motor can automatically tune. The
controller only automatically counts three parameters: stator resistance, rotor resistance, and
leakage inductance. It automatically counts mutual inductance and no-load current of motor as
well.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Suzhou Monarch Control Technology MCTC-CTB-A and is the answer not in the manual?

Suzhou Monarch Control Technology MCTC-CTB-A Specifications

General IconGeneral
BrandSuzhou Monarch Control Technology
ModelMCTC-CTB-A
CategoryController
LanguageEnglish

Related product manuals