System typical application and adjustment NICE3000 User Manual
170
The setting of the highest, lowest and service oor
When two lifts are in parallel, if the oor structure is different, the F6-01 setting of
the lowest oor should be the same with the external call dial code of the corresponding lifts
lowest oor. The setting of the highest oor should be the same with the corresponding physical
oors oor number of the highest oors external call dial code.
Following the principles mentioned above, the lifts
corresponding setting in the example
should be:
No.1 lift F6-00=4 6-01=1, No.2 lift F6-00=5 F6-01=2
3. The setting of service oor
As the instruction in 1, the Floor 2 of the No.2 lift in the example has the leveling plate but no
oor door, so it is no service oor, and needs to set service oor F6-05=65533.
7.6 Instruction of group control program
Details refer to the instruction of group control
7.7 Instruction of overload and full load
In order to facilitate the use of different users, NICE 3000 integrated controller supplies three
over load and full load signals inputting mode to fulll these functions. When in use, correctly
set the corresponding parameters to avoid miss-operation. Briefly explain its use in the
following:
7.7.1 Car top switchs terminal inputting mode:
When F5-36 is
setting as 1, select car top switch inputting mode to fulll over load.
The car top board of NICE 3000 (MCTC-CTB-A) has 8 switch inputting terminals (CN3). Among
those, the corresponding function of X7 terminal is full load signal, and that of X8 is over load
signal. The properties of these inputting terminals are dened by function code (F5-25). If the
F5-25s parameter BIT6=1, the car top board s
ignal X7 is N.O.; If the F5-25s parameter
BIT6=0, the car top board signal X7 is N.C. The properties of over load signal X8 are the same.
Relationship is as follows, and the X in the following chart means any number:
Over load switchs
property
F5-25 correct
parameters setting
Car top board X8
terminals inputting
voltage (V)
NICE 3000 state
N.O.
1xxx,xxxx 24V Over load state
1xxx,xxxx 0V Normal state
N.C.
0xxx,xxxx 24V Normal state
0xxx,xxxx 0V Over load state
Suitable for car top board switch signal, to fulll overload and full load needs set F5-36=1.
7.7.2 Main control board switchs terminal inputting mode:
There are 24 swi
tch inputting terminals (CN1, CN9) of NICE 3000 integrated controllers
main control board. Each terminal has more than 60 function selections. Details refer to the

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Suzhou Monarch Control Technology MCTC-CTB-A and is the answer not in the manual?

Suzhou Monarch Control Technology MCTC-CTB-A Specifications

General IconGeneral
BrandSuzhou Monarch Control Technology
ModelMCTC-CTB-A
CategoryController
LanguageEnglish

Related product manuals