Binary bit Meaning Binary bit Meaning
Bit4 Lift state:
0: inspection; 1:shaft auto-
tuning;
3:fire arrival main oor;
4:firemen; 6:motorman ;
7:normal
Bit12 System full load
Bit5 Bit13 System over load
Bit6 Bit14 Reserved
Bit7 Bit15 Reserved
Pre-torque current; it reects the percentage of compensational pre-torque current to the rated
current when the lift starts to run, with the unit %.
FA-03
Pulse wheel encoder currently
angle
Default 0.0° Min. Unit 0.1°
Setting Range 0.0~360.0°
It displays the current factual angle of the encoder. User cannot amend it.
Function code Name Setting Range Default Min. Unit
FA-04 Software edition 1(FK) 0~65535 0 1
FA-05 Software edition 2(ZK) 0~65535 0 1
FA-06 Software edition 3(DSP) 0~65535 0 1
FA-07 Radiator temperature 0~100℃ 0 1℃
It displays the software edition NICE3000 is using.FA-07 displays radiator’s current
temperature.
6.12 FB Group Door Function Parameters
FB-00
Door machine number Default 1 Min. Unit 1
Setting Range 1~2
It can set the number of door machine. User can set this function parameter by actual using
number of door machine.
FB-02
Front door service oor 1 Default 65535 Min. Unit 1
Setting Range 0~65535(set 1~16 oor)
This function code is made up of binary numbers with 16 emic that control those oors allowing
front door to open normally within oor 1 to oor 16. Every oor door is controlled by one binary
number.
1:Relevant oor’s front door can be open.
0:Forbidden relevant oor’s front door open.
Its setting way is the s
ame with F6-05; details are shown in section 6.7.
Notice: this parameter shouldn’t clash with F6-05 and F6-06 when user‘s setting! It’s
required to ensure that door machine’s service oor is the system service oor.