Function parameters tables NICE3000 User Manual
94
Function
Code
Name Setting Range Min. Unit Default
Modi-
cation
FB-09
Door open/
close times
020 1 0
FB-10
Run main
landing door
state
0: open the door normally
1: waiting for opening the door
1 0
FB-11
Time keeping
for hall call door
opening
130s 1s 5s
FB-12
Time keeping
for internal call
door opening
130s 1s 3s
FB-13
Time keeping
for opening at
main landing
(main landing is
used including
Single Lift,
Group Control
,
and Lock Lift)
130s 1s 10s
FB-14
Delay time for
open keeping
101000s 1s 30s
FC Protect Function Parameters
FC-00
Earth short
circuit
protection
detection after
power on
0Forbidden;
1Allowable
1 1
FC-01
Protection
selection
Bit0Overload protection selection
0Forbidden
1Allowable
Bit1Output phase-failure selection
0Phase-failure protection
1:Phase-failure unprotected
Bit3: E053 add door-close limit judgment
0
:no new method
1:old method + old method
Bit4: door-closing limit judge light curtain
0:no re-opening
1:re-open the door
Bit5: DSP communication judgment
0:wire broken check
1:no check
Bit6: new method for parallel door block
0: use mew method
1: resume to 745 program
Bit7:reveling over-speed check
0:check
1:no check
1 1
FC-02
Overload
protection
coefcient
0.5010.00 0.01 1.00
FC-03
Overload
pre-warning
coefcient
50100% 1% 80%
FC-04
Error self-
resetting times
0Means that the system forbidden auto-
resetting function;
010
1 0
FC-05
Reset interval
time
220s 1s 5s