3-18
Compression Damping Force
Adjustment
To set the adjuster, you must gen-
tly turn the adjust screw 1 clock-
wise until it stops, then back it out
the recommended number of
turns. Do not force the adjust
screw 1 past the stopped posi-
tion, or you may damage the
adjuster.
 Standard setting:
counterclockwise 1-1/2
turns
Rebound Damping Force
Adjustment
To set the adjuster, you must gen-
tly turn the adjust screw 2 clock-
wise until it stops, then back it out
the recommended number of
turns. Do not force the adjust
screw 2 past the stopped posi-
tion, or you may damage the
adjuster.
 Standard setting:
counterclockwise 3 turns