4. Modules
Integral part of original HP-41 are pluggable modules. This chapter explains how to load and
manage modules in DM41X.
4.1. Quick Module Load
This is quick step by step reference how to load module.
You can use [ ▲ ], [ ▼ ] keys to navigate items.
Plug , Imprt , etc. corresponds to soft menu items and are activated by respective first-row key.
Steps
Load .mod file to DM41X
1. First you need to prepare module as .mod file
2. Copy .mod file to calculator’s FAT disk (preferably to the /MODS directory)
See Activate USB disk how to copy files to calculator’s FAT disk.
Load .mod file to internal Flash Module area
3. Navigate to SETUP Module Active Modules Plug Imprt
4. Select .mod file from the file list, press [ENTER] to load.
Now you should see list of modules present in Flash Module area
Add module to the 'Active Modules' list
5. Select your module and press Add key from soft menu. You should see Active Modules screen
6. Press [ENTER] to accept Active Modules list.
Now the module should be active.
4.2. Plug-in Printer Module
This is quick step by step reference how to activate printer module.
Steps
1. Navigate to SETUP Module Active Modules.
2. Press Plug .
3. Select Thermal Printer and press Add or [ENTER]
Thermal Printer module should be in Active Modules list now.
4. Press [ENTER] to accept new Active Modules list.
17