P113 input IN4
Function of the digital input IN4
Values: Description:
Off Input has no function
Counter-clockwise CCW rotation (24 V = CCW)
Reset Reset (pulse at 24 V = trigger reset)
Motor coding Frees up the input for the motor coding, the input has the value Bit1
P114 input IN5
Function of the digital input IN5
Values: Description:
Off Input has no function
Counter-clockwise CCW rotation (24 V = CCW)
Reset Reset (pulse at 24 V = trigger reset)
Motor coding Frees up the input for the motor coding, the input has the value Bit2
Fixed frequency Frees up the input for the choice of the fixed frequency, the input has the value Bit1
P115 input IN6
Function of the digital input IN6
Values: Description:
Off Input has no function
Counter-clockwise CCW rotation (24 V = CCW)
Reset Reset (pulse at 24 V = trigger reset)
Motor coding Frees up the input for the motor coding, the input has the value Bit3
Fixed frequency Frees up the input for the choice of the fixed frequency, the input has the value Bit0
P120 relay REL1
Output value of relay REL1
Values: Off:
- No function, relay is in opened state.
Operation:
- The inverter is ready for operation, the motor can be started.
Warning:
- The inverter is in warning state, the motor can be started.
Failure:
- The inverter is in the error state, the motor cannot be started and a reset is
required.
Overload:
- The motor current has reached the current limit. (P44-I_limit, -10% hysteresis).
N_rated reached:
- The actual speed of the motor has reached the rated speed
(P14-f_motor = P10-N_rated_act, ±10% hysteresis).
Current limit:
- The real motor current is higher than the current warning threshold (P18-I_mot
>= P125-I_warning, 10% hysteresis).
Motor temperature:
- The temperature sensor in the motor indicates that the temperature is too high
(see P85-motorprotection and P86-R_protect).