Table 11-1
Steps for restoring power to an appliance following a power
interruption (continued)
DescriptionActionStep
Once you have verified that the status of the
appliance hardware is healthy, check to make
sure that all NetBackup services have resumed.
All backup jobs resume once the appliance is
turned on.
You can check the NetBackup services through
the Command Line Interface or the maintenance
shell menu.
Note: If a backup was in process when the power
interruption occurred, the backup job likely failed.
Verify that all NetBackup
services have started.
Step 3
Power restoration procedures
Use the following procedures as a guide to walk through restoring power to your
hardware:
Restoring operation to a NetBackup appliance following a
power outage
This section describes how to restore operation to a NetBackup appliance after the
source power is restored following a power outage.
To restore a standalone appliance following a power outage
1
Make sure that source power is available to the unit and that the unit is turned
off.
Note: On the control panel, the LEDs for the Ethernet ports (1, 2, and 3) that
are connected are green. The system status LED is also green.
2
Press the power button on the control panel. The fans turn on as the unit starts
initiation.
See “Restoring operation to a NetBackup appliance with external storage following
a power outage” on page 119.
See “Troubleshooting Hardware Issues” on page 91.
118Disaster Recovery