03:00.0 Fibre Channel: QLogic Corp. ISP2532-based 8Gb Fibre Channel
to PCI Express HBA (rev 02)
03:00.1 Fibre Channel: QLogic Corp. ISP2532-based 8Gb Fibre Channel
to PCI Express HBA (rev 02)
06:00.0 Fibre Channel: QLogic Corp. ISP2532-based 8Gb Fibre Channel
to PCI Express HBA (rev 02)
06:00.1 Fibre Channel: QLogic Corp. ISP2532-based 8Gb Fibre Channel
to PCI Express HBA (rev 02)
**** Drivers ****
qla2xxx is loaded
windrvr6 is loaded
**** Ports ****
Bus ID Slot Port WWN Status Mode Speed Remote Ports
2:00.0 Slot3 21:00:...:07 Linkdown Initiator 4 gb/s
2:00.1 Slot3 21:01:...:07 Linkdown Initiator 4 gb/s
3:00.0 Slot2 21:00:...:30 Disconnect Target 8 gb/s
3:00.1 Slot2 21:00:...:31 Online Initiator 2 gb/s 0x21000024...
6:00.0 Slot1 21:00:...:82 Fabric Target 8 gb/s
6:00.1 Slot1 21:00:...:83 Online Initiator 8 gb/s 0x21000024...
*** Devices ****
Device Vendor Host Type Remote Port
/dev/sg0 SYMANTEC 10.182.0.209 FCPIPE (NBU 50x0) 0x21000024ff232438
/dev/sg2 SYMANTEC 10.182.0.209 FCPIPE (NBU 50x0) 0x21000024ff3162be
*** Notes ****
(NOTE: Ports in mode "Initiator*" are configured for target mode
When SAN Client FT Media Server is active, however, are currently
running in initiator mode, i.e. SAN Client is disabled or inactive.)
About Notification settings
You can use the Settings > Notification > Alert Configuration from the NetBackup
Appliance Web Console to apply the Call Home settings. AutoSupport in appliance
uses the data that is gathered by Call Home to provide proactive monitoring for the
appliance. If Call Home is enabled, the appliance uploads hardware and software
information (or the Call Home data) to Symantec AutoSupport server periodically
at an interval of 15 minutes.
If the appliance encounters an error state, all hardware logs from past three days
are gathered along with the current log. The logs are then uploaded to the Symantec
23Best practices
About Notification settings