APPENDIX C
5. Wait approximately one minute between each adjustment to allow the oscillator to stabilize.
6. Keep adjusting the oscillator in the appropriate direction until the DAC value is
approximately at its midpoint (32767).
7. Install the screw in the oscillator adjustment access hole.
8. If after approximately one hour, the DAC value has changed by more than ±5,000 from
32767, repeat steps one through six.
C-30 ET6xxx ExacTime GPS TC & FG (Rev C) Symmetricom Inc