EasyManuals Logo

Symmetricom ET6000 User Manual

Symmetricom ET6000
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
CHAPTER FOUR
The user enters $H (HEX 24/HEX 48) followed by abcd where:
a = baud rate (0-7)
0 = 50
1 = 300
2 = 600
3 = 1200
4 = 2400
5 = 4800
6 = 9600
7 = 19200
b = number of data bits
0 = 7
1 = 8
c = parity
0 = none
1 = odd
2 = even
d = number of stop bits
0 = 1
1 = 2
4.39 PRINTER – REQUEST CONFIGURATION
This command allows the user to request the current printer set-up. It is applicable to both the
Standard RS232 Printer Output and the One Second Burst RS232 ASCII Time Output.
The user enters $I (HEX 24/HEX 49).
The unit responds with: 09600 8/7 N/O/E 1/2<CR><LF>.
(Baud Rate) (8 or 7 data bits) (none, odd, or even parity) (1 or 2 stop bits)
(carriage return) (line feed).
4.40 PRINTER PORT MODE SELECTION
This command allows the user to specify the printer mode or output format . The selection is
either “Standard” or “One Second Burst”. For a detailed description of these two formats, refer
to Chapter Three – Operation.
4-20 ET6xxx ExacTime GPS TC & FG (Rev C) Symmetricom Inc