SYNRAD® 32-1 Operator’s Manual Version 2.2
60
Troubleshooting
Maintenance/
Troubleshooting
Input/Output/Fault Conditions
Remote Key
PWM
Fault
Ready LED
Lase LED
DB-9 pins
6 to 7 3 to 4
1 9 8
DC Power Off X X
Laser enabled, no tickle or
PWM
C None H ON
Tickle Applied C Tickle H ON Tickle
Laser Firing C H ON
Over Temp Fault X X L
Under Voltage Fault X X L
Over Voltage Fault X X L
3/24/2017
H = output high/open
L = output low
LASER CONDITION /
FAULT
OUTPUT STATUS
INPUT STATUS
DC Power Applied Laser
Not Enabled
H ON
C = circuit closed
O = circuit open
x = Does not matter
O X
L