appendix a
A3
Synrad
Series 48Series 48
Series 48Series 48
Series 48 operator’s manual
Closed Loop Stabilization Kit
Connecting
Refer to Figure A-1 for an illustration showing a typical closed loop system and then perform the follow-
ing steps:
Figure A-1 Typical closed loop setup
SYNRAD Laser
CL
Kit
Beam
Blocker
Laser
Power Supply
UC-2000 Universal
Laser Controller
C/L GateLaser
ANV/
ANC
If RequiredIf Required
1
Disconnect power from your laser and the UC-2000 Controller.
2
Connect one end of the CL Interconnect cable to the laser-mounted closed loop assembly and the
other end to the UC-2000’s 8-pin mini-DIN C/L connector.
3
If required, connect a gating signal to the UC-2000’s Gate BNC connector.
4
If required, connect an ANV signal from your analog voltage source to the UC-2000’s ANV/ANC
BNC connector.
5
Set the UC-2000 to MAN. CLOSED or ANV CLOSED mode.
6
Apply power to both the laser and UC-2000 and then verify proper system operation.