getting started
113
Synrad
Series 48Series 48
Series 48Series 48
Series 48 operator’s manual
Connecting
1
Verify that input AC to the DC power supply is physically locked out or disconnected.
2
Locate the 30 VDC output terminals on the power supply’s output section and connect the black
(–) DC Power cable from the laser to the negative (– COM) output terminal.
3
Connect the red (+) DC Power cable from the laser to the positive (+ V1) 30 VDC output termi-
nal.
4
Connect the AC line cord to the AC receptacle located on the fan end of the DC-1 power supply.
Note: U.S., European, and UK line cords are available for the DC-1 power supply. If the line cord
provided does not fit your available AC outlet, you will need to provide a cable with the proper
AC outlet plug on one end and a standard IEC 320 female connector on the power supply end.
DC-2 / DC-5 power supply
To connect either the DC-2 or DC-5 power supply for 120 VAC (low range) input, refer to Figure 1-6
and follow the steps listed in the 120 VAC input operation section. If you are connecting the DC-2/DC-5
power supply for 240 VAC (high range) input, refer to Figure 1-6 and follow the steps listed in the 240
VAC input operation section.
Note: Because AC input connections and requirements vary from facility to facility, our DC-2 and
DC-5 power supplies do not include an AC power cord. Customers must provide the appropri-
ately sized AC power cable or wiring.
Figure 1-6 DC-2/DC-5 (Power-One) power supplies
1
2
L
3
2
1
10
11
12
N
Input Section
3
2
14
5
6
+
VOLT
ADJ.
Output Section
SYNRAD DC-2 DC Power Supply
1
2
L
3
2
1
10
11
12
N
Input Section
3
2
14
5
6
+
VOLT
ADJ.
Output Section
SYNRAD DC-5 DC Power Supply
1
2
3
4
3
2
14
5
6
VOLT
ADJ.
120 VAC input operation
1
Verify that input AC power to the DC power supply is physically locked out or disconnected.
2
Locate the 30 VDC output terminals on the power supply’s output section and connect the black
(–) DC Power cable from the laser to the negative (–) output terminal.
3
Connect the red (+) DC Power cable from the laser to the positive (+) 30 VDC output terminal.

Table of Contents