Overview of the TAC 200 as a controller for various heating systems.
Describes the contents of the manual, chapter by chapter.
Instructions for mounting the TAC 200 controller and associated sensors.
Wiring diagrams for connecting the TAC 200 to actuators and sensors.
Details electrical specifications like supply voltage, power consumption, and input/output characteristics.
Provides mechanical specifications such as enclosure dimensions, rating, and weight.
Lists default settings for various P-functions after a restart.
Lists available part numbers for the TAC 200 and its accessories.
Overview of the TAC 200 as a controller for various heating systems.
Describes the contents of the manual, chapter by chapter.
Lists other relevant documents for the TAC 200.
Instructions for mounting the TAC 200 controller and associated sensors.
Instructions for mounting various types of sensors for the TAC 200.
Wiring diagram for connecting to a mixing valve system.
Wiring diagram for connecting to a 24V actuator system.
Wiring diagram for connecting to an on/off control system.
Details connections on the terminal unit and cable length considerations.
Description of the controller's display, keys, and their functions.
Explains the meaning of symbols and segments used on the TAC 200 operator panel.
Details DIP-switch settings and initial checks before system operation.
Procedure for setting the current time and date on the controller.
Lists the P-functions from P:00 to P:15 that can be accessed and modified.
Provides detailed explanations for P:00 to P:08 functions and their operation.
Explains P:09 to P:12 Time programs and how to set them.
Details setting time programs for 1-7 days (P:10, P:12).
Lists special functions and parameters from P:16 onwards used for commissioning and adjustments.
Explains how to reset the controller to default values using P:54.
Describes the three main control functions: power, room, and supply water temperature.
Explains how the control curve determines supply temperature based on outdoor temperature.
Details control curve adjustment parameters like max/min supply temps and curve points.
Describes how to measure and control power consumption against a preset limit.
Explains using digital input X3 for pulse counting to calculate current power.
Details parameters for limiting power consumption via PI controller.
Describes how the controller regulates room temperature using supply water temperature.
Details parameters for room sensor authority, I-time, deadzone, and influence limits.
Explains how to set night setback SP and morning boost based on room or supply temperature.
Details outdoor temperature limits for night setback and morning boost, and boost parameters.
Describes how to extend day or night operation via external signals.
Explains using Time program 2 to control external units like heating or fans.
Details pump operation, stop conditions, start conditions, and anti-freeze protection.
Covers time format display and Daylight Saving Time settings.
Explains test functions for program version, manual output control, and display testing.
Details electrical specifications like supply voltage, power consumption, and input/output characteristics.
Provides mechanical specifications such as enclosure dimensions, rating, and weight.
Lists default settings for various P-functions after a restart.
Lists default settings for various P-functions after a restart.
Lists available part numbers for the TAC 200 and its accessories.
Details DIP-switch settings for various operating modes and system types.
Lists default and new values for room setpoints and curve adjustment.
Defines day operation times for Time Program 1 and 2.
Lists default values for power limiting parameters.
Lists default values for room sensor authority and influence parameters.
Lists default values for supply temperature control parameters.
Lists default values for night setback and morning boost parameters.
Lists default values for pump control parameters.
Lists default values for time format and DST settings.