Parameter
address
Parameter
Code
Description
Default
value
Max. value Min. value Unit Note
620C FU1 #12 DcSt value 50 200 0 1%
620D FU1 #13 DcSt time 0 600 0 0.1sec
6214 FU1 #20 Max freq. 5000 40000 4000 0.01Hz
6215 FU1 #21 Base freq. 5000 FU1-20 3000 0.01Hz
6216 FU1 #22 Start freq. 10 1000 10 0.01Hz
6217 FU1 #23 Freq limit 0 1 0
6218 FU1 #24 F-limit Lo. 0 FU1-25 0 0.01Hz
6219 FU1 #25 F-limit Hi. 5000 FU1-20 FU1-24 0.01Hz
621A FU1 #26 Torque boost 0 1 0
621B FU1 #27 Fwd boost 50 150 0 0.1%
621C FU1 #28 Rev boost 50 150 0 0.1%
621D FU1 #29 V/F pattern 0 2 0
621E FU1 #30 User freq. 1 1250 FU1-32 0 0.01Hz
621F FU1 #31 User volt. 1 25 100 0 %
6220 FU1 #32 User freq. 2 2500 FU1-34 FU1-30 0.01Hz
6221 FU1 #33 User volt. 2 50 100 0 %
6222 FU1 #34 User freq. 3 3750 FU1-36 FU1-32 0.01Hz
6223 FU1 #35 User volt. 3 75 100 0 %
6224 FU1 #36 User freq. 4 5000 FU1-20 FU1-34 0.01Hz
6225 FU1 #37 User volt. 4 100 100 0 %
6226 FU1 #38 Volt control 1000 1100 40 %
6227 FU1 #39 Energy save 0 30 0 %
6232 FU1 #50 ETH select 0 1 0
6233 FU1 #51 ethperc 180 250 FU1-52 %
6234 FU1 #52 contperc 120 FU1-51 50 %
6235 FU1 #53 Motor type 0 1 0
6236 FU1 #54 OL level 150 250 30 %
6237 FU1 #55 OL time 100 300 0 0.1sec
6238 FU1 #56 OLT select 0 1 0
6239 FU1 #57 OLT level 200 250 30 %
623A FU1 #58 OLT time 600 600 0 0.1sec
623B FU1 #59 Stall prev. 0 7 0
623C FU1 #60 Stall level 200 250 30 %