If the TX1 detects any bad sectors on the source drive, it adds a section at the end of the job
log. This additional section lists the sector address and sector length of each unreadable region
of the source drive. Note that if error retries are enabled and the TX1 is able to successfully
read sector data after an initial read error is encountered, the Total recoverable errors count
will reflect the number original read errors encountered. The Total unrecoverable errors count
reflects read errors for which no retry attempts were successful.
It is a best practice to export and delete logs from the TX1 after each case. The TX1 will store
100 logs before overwriting logs. Once a log is deleted, the data is unrecoverable.