200 Frequency Synthesizer Fault Finding TM8100/TM8200 Service Manual
© Tait Electronics Limited November 2007
Task 8 —
Reference
Frequency
If the supply for the charge pump is correct, check the reference frequency
input from the FCL to the PLL.
1. Measure the reference frequency at pin 8 of IC503 (see Figure 9.2).
2. If the signal is correct, go to Ta s k 9
. If it is not, go to Step 3.
3. Check IC503 (see Figure 9.2). Replace IC503 if it is suspect.
4. Determine if the fault has been removed. If it has, go to “Final Tasks”
on page 163. If it has not, the FCL is suspect; go to “Power Supply
for FCL” on page 234.
Figure 9.7 Components between the digital board and the frequency synthesizer
VIAS FOR
MEASUREMENTS
FCL TOP CAN
pin 8 of IC503: 13.012 ± 0.002 MHz and 1.1 ± 0.2V
pp
A4 band: pin 8 of IC503: 2.612 ± 0.002 MHz and 1.1 ± 0.2V
pp