(SDM control)
0 0 Disable SDM output on reception. Yes
1 Enable SDM output on reception, QUERY
command not required.
Yes
1 0 Disable SDM caller ID encode. Yes
1 Enable SDM caller ID encode. The caller ID
is sent as a separate SDM before sending
the SDM itself.
Yes
2 0 Disable SDM caller ID decode. Yes
1 Enable SDM caller ID decode. The caller ID
SDM is decoded before the incoming SDM.
Yes
2
(emergency
mode)
2 0 Activate non-stealth emergency mode. Yes
1 Activate stealth emergency mode. Yes
3
(simulate key
presses)
none 000-009 PTT keypress length, 0=constantly off, 1-
8=x/8 seconds on, 9=constantly on.
Yes
010-019 Hookswitch keypress length, 0=constantly
off,
1-8=x/8 seconds on, 9=constantly on.
Yes
020-029 ‘On/off’ keypress length, 0=constantly off,
1-8=x/8 seconds on, 9=constantly on.
Yes
030-039 ‘Up’ keypress length, 0=constantly off,
1-8=x/8 seconds on, 9=constantly on.
Yes
040-049 ‘Down’ keypress length, 0=constantly off,
1-8=x/8 seconds on, 9=constantly on.
Yes
050-059 ‘FN1’ keypress length, 0=constantly off,
1-8=x/8 seconds on, 9=constantly on.
Yes
060-069 ‘FN2’ keypress length, 0=constantly off,
1-8=x/8 seconds on, 9=constantly on.
Yes
070-079 ‘FN3’ keypress length, 0=constantly off,
1-8=x/8 seconds on, 9=constantly on.
Yes
080-089 ‘FN4’ keypress length, 0=constantly off,
1-8=x/8 seconds on, 9=constantly on.
Yes
[FUNCTION] [SUBFUNCTION] [QUALIFIER] Action Support