54 CCR TM8100/TM8200 Computer-Controlled Data Interface (CCDI) Protocol Manual
© Tait Electronics Limited April 2007
Tx power level
Channel bandwidth
The unit can accept or send Selcall in:
All the international tone formats
Between 2 and 8 tones per sequence.
Tone durations from 20 - 100ms
ANI leading/trailing sequence
Other features:
Audio volume level
Enable/disable monitor
2.1.2 Potential Applications
Complex conventional radio units (multi-system)
MDT controlled radio
Remote off-air monitoring
System integration
Self healing RF networks
Rapid deployment - inter operability
Hybrid solutions
2.2 Programmable Parameters
CCR depends on the same programmable parameters as those used to
configure CCDI command mode.
2.2.1 Requirements
The following needs to be enabled as a minimum:
Enable CCDI
Enable a serial port for communications (Auxiliary, Mic or Internal
Options connector) as follows:
Note The recommended configuration parameters are in Bold.
Parameter Value
Baud rate 1200, 2400, 4800, 9600, 14400, or 19200
Number of data bits 8
Parity None
Number of stop bits 1