Sizethegaspipeappropriatelytosupplythenecessaryvolumeofgasrequiredfor
thewaterheaterusingANSI233.1/NFPA54intheUSAorCAN/CSAB149.1inCanada
orlocalcodes.Otherwise,flowcapabilitiesandoutputtemperatureswillbelimited.
Checkthatthetypeofgasmatchestheratingplatefirst.
Ensure that any and all gas regulators used are operating properly and
providing gas pressures within the specified range shown below. Excess gas
inletpressuremaycauseseriousaccidents.
Conversion of this unit from natural gas to propane or vise versa will void all
warranty. Contact your local distributor to get the correct unit for your gas
type.The manufacturer is not liable for any property and/or personal
damageresultingfromgasconversions.
GASSUPPLYANDGASPIPESIZING
General‐
Theminimumandmaximuminletgaspressuresare:
Gastype Inletgaspressure
NaturalGas Min.5.0”WCMax.10.5”WC
Propane Min.8.0”WCMax.14.0”WC
Gas pressure above this specified range for the water heater and/or insufficient gas volume will
adversely affect performance.These pressures are measured when the water heater is in full
operation.
Inlet gas pressure must not exceed the above maximum values; gas pressure above the specified
rangewillcausedangerous
operatingconditionsanddamagetotheunit.
Until testing of the main gas line supply pressure is completed, ensure the gas line to the water
heaterisdisconnectedtoavoidanydamagetothewaterheater.
Gasconnections‐
1. Installamanualgasshutoffvalvebetweenthewaterheaterandthegassupplyline.
2. When the gas connections are completed, it is necessary to perform a gas leak test (see below)
eitherbyapplyingsoapywatertoallgasfittingsandobservingfor bubblesor byusing
a gasleak
detectiondevice.
Thewaterheater anditsindividualshutoff valvemustbe disconnected fromthe gassupply
pipingsystemduringanypressuretestingofthatsystemattestpressures inexcessof1/2psi
(3.5kPa).
Thewaterheatermustbeisolatedfromthegassupplypipingsystembyclosingitsindividual
manual shutoff valve during any pressure testing of the gas supply piping system at test
pressuresequaltoorlessthan1/2psi(3.5kPa).
3. Alwayspurgethegaslineofanydebrisand/orwater
beforeconnectingtothegasinlet.