Troubleshooting
37Page
GENERAL
TROUBLESHOOTING
TEMPERATUREandAMOUNTOFHOTWATER
PROBLEM SOLUTIONS
Ittakeslongtimetoget
hotwateratthe
fixtures.
Thetimeittakestodeliverhotwaterfromthewaterheaterto
yourfixturesdependsonthelengthofpipingbetweenthetwo.
Thelongerthedistanceorthebiggerthepipes,thelongeritwill
take
togethotwater.
Ifyouwouldliketoreceivehotwatertoyourfixturesquicker,you
maywanttoconsiderahotwaterrecirc ulationsystem.(p.28)
Thewaterisnothot
enough.
Comparetheflowandtemperature.Seethechartsonp.4849.
Checkcrossplumbingbetweencoldwaterlinesandhotwater
lines.
Isthegassupplyvalvefullyopen?(p.30)
Isthegaslinesizedproperly?(p.18)
Isthegassupplypressure
enough?(p.19)
Isthesettemperaturesettoolow?(p.3334)
Thewateristoohot.
Isthesettemperaturesettoohigh?(p.3334)
Thehotwaterisnot
availablewhenafixture
isopened.
Makesuretheunithas120VAC/60Hzpowersupply.
Ifyouareusingtheremotecontroller,isthepowerbuttonturned
on?
Isthegassupplyvalvefullyopen?(p.30)
Isthewatersupplyvalvefullyopen?(p.30)
Isthe
filteroncoldwaterinletclean? (p.36)
Isthehotwaterfixturesufficientlyopentodrawatleast0.75GPM
throughthewaterheater?(p.33)
Istheunitfrozen?(p.35)
Isthereenoughgasinthetank/cylinder?(ForPropanemodels)
Thehotwaterturns
coldandstayscold.
Istheflowrateenoughtokeepthewaterheaterrunning?(p.33)
Ifthereisarecirculationsysteminstalled,doestherecirculation
linehaveenoughcheckvalves?(p.28)
Isthegassupplyvalvefullyopen?(p.30)
Isthefilteroncoldwaterinletclean?
(p.36)
Arethefixturescleanofdebrisandobstructions?
Checkiftheflowrateistoolow.(p.3334)
Fluctuationinhotwater
temperature.
Isthefilteroncoldwaterinletclean?(p.36)
Isthegaslinesizedproperly?(p.18)
Isthesupplygaspressuresufficient?(p.19)
Checkforcrossconnectionbetweencoldwaterlinesandhotwaterlines.