25 INSPECT/DUMP & INITIALIZE
INSPECT or DUMP
These functions allow inspection of Record Data registers and/or data
transfer to a PC. To use this function: Press and hold CAL and REC keys
together for two seconds to INSPECT data. Momentarily press the MARK
key to sequence up through positions. Momentarily press the REC key to se-
quence down through positions. To sequence up or down in multiples of ten
positions, momentarily press the HOLD key for up and CAL key for down.
Momentarily press the CAL and REC keys together to DUMP data to a PC.
INITIALIZE
This function resets all user settings to default values providing an easy way
to escape from an unwanted function. It will be necessary to re-calibrate
after you initialize. Place the Measurement Module back down on a at sur-
face and press the entire top row of keys for two seconds with two ngers
from each hand.
INSPECT/DUMP 26
RECORDING DATA ‘ON THE FLY’
When ZIPLEVEL registers ll, ‘FULL will display
but record data to PC can continue indenitely.
CAL
REC
MARK
HOLD
Press CAL and REC two seconds to enter or exit INSPECT
Press CAL and REC momentarily and release to DUMP data to PC
Sequence
down
Sequence
up
TENS ONES ONES TENS
INSPECT POSITION CONTROL KEYS
PC Serial Link
Compact PC mounted to Unipod in left hand
or in pocket with display visible to operator
INSPECT
/DUMP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Technidea ZIPLEVEL PRO-2000 and is the answer not in the manual?

Technidea ZIPLEVEL PRO-2000 Specifications

Ranges IconRanges
set-up vertical range40’ (12m)
set-up horizontal range200’ (60m)
carry function rangeNo limit
Accuracy IconAccuracy
reading repeatability0.1” (2mm) or 0.01” (0.2mm) HP
leveling accuracy0.1” (2mm) or 0.01” (0.2mm) HP
elevation accuracyGreater of 0.1” (2mm)/0.01” (0.2mm) HP or 0.2% reading <10’ (3m) & 0.35% reading >10’
Capacity IconCapacity
record capacity16, 384
record data capacity137 readings
settings/data retentionIndefinitely, even without battery
Operating Environment IconOperating Environment
operating temperature range-22°F to +158°F (-30C to +70C)
storage temperature range-40°F to +158°F (-40C to +70C)
shock resistanceMeasurement Module – 5’ (2m) drop on concrete
Battery IconBattery
battery type9V alkaline
battery life60 hours active use