Technidea Corporation warrants the ZIPLEVEL
®
PRO-2000 High Precision
Altimeter against deciencies in materials and workmanship for one year
from the date of purchase. The ZIPLEVEL
®
hydro-pneumatics are covered
by a second year pro-rata warranty.
ZIPLEVEL
®
never requires factory calibration and normal use should allow
years of use without repair. Every 2 - 3 years ZIPLEVEL
®
will ash “CORD
on the display indicating a need for a factory recharge of its hydro-pneumat-
ics. For detailed warranty information, the location of your nearest service
center and shipping information, visit www.ziplevel.com/service.
PRODUCT ASSISTANCE
If you have difculty using your new ZIPLEVEL
®
after reading this User
Guide then please email info@ziplevel.com or call 1.800.805.LEVEL(5383)
or 1.760.480.4740 outside the USA.
MADE IN THE USA
37 MAINTENANCE/PRODUCT ASSISTANCE SPECIFICATIONS 38
Set-up vertical range: 40’ (12m) (20’ (6m) above and below Base Unit)
48”(122cm) full range in High Precision (HP)
Set-up horizontal range: 200’ (60m) dia. Circle, (150’ (46m) PRO-2000B)
Carry function range: No limit
Range of zero or mark: Full vertical range
Reading repeatability: 0.1” (2mm) or 0.01” (0.2mm) HP typical
Leveling accuracy: 0.1” (2mm) or 0.01” (0.2mm) HP typical
Elevation accuracy: Greater of 0.1” (2mm)/0.01” (0.2mm) HP or 0.2%
reading <10’ (3m) & 0.35% reading >10 typ.
Record capacity: 16,384 with no practical limits
Record data capacity: 137 readings
Settings/data retention: Indenitely, even without battery
Operating temp. range: -22°F to +158°F (-30C to +70C)
Storage temp. range: -40°F to +158°F (-40C to +70C)
Shock resistance: Measurement Module – 5’ (2m) drop on concrete
Base Unit – 3’ (1m) drop on concrete
Water resistance: Rain tight; not immersible
9V alkaline battery life: 60 hours active use (auto shut-off after
4 minutes inactive)
U.S. Patents: 4,878,297; 5,517,869; 5,726,365; 5,844,150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Technidea ZIPLEVEL PRO-2000 and is the answer not in the manual?

Technidea ZIPLEVEL PRO-2000 Specifications

Ranges IconRanges
set-up vertical range40’ (12m)
set-up horizontal range200’ (60m)
carry function rangeNo limit
Accuracy IconAccuracy
reading repeatability0.1” (2mm) or 0.01” (0.2mm) HP
leveling accuracy0.1” (2mm) or 0.01” (0.2mm) HP
elevation accuracyGreater of 0.1” (2mm)/0.01” (0.2mm) HP or 0.2% reading <10’ (3m) & 0.35% reading >10’
Capacity IconCapacity
record capacity16, 384
record data capacity137 readings
settings/data retentionIndefinitely, even without battery
Operating Environment IconOperating Environment
operating temperature range-22°F to +158°F (-30C to +70C)
storage temperature range-40°F to +158°F (-40C to +70C)
shock resistanceMeasurement Module – 5’ (2m) drop on concrete
Battery IconBattery
battery type9V alkaline
battery life60 hours active use
auto shut-off time4 minutes inactive