21 CARRY
The CARRY function lets you leap-frog the Measurement Module and Base
Unit to measure elevations (differential level) over any distance or elevation
on earth without tabulation, computations or loss of your original benchmark
plane. Two people working together can traverse terrain at a 2 mph (3 kph)
rate.
To use the CARRY function follow the steps in the illustration. Repeat the
HOLD and ZERO sequence over any distance or elevation. You may keep
the Base Unit vertical for ease of leap-frogging if it was vertical when setting
the benchmark.
To exit CARRY within any set-up, press and hold the ZERO key for two
seconds without the HOLD indicator showing. You can then do a new set-up
zero without loss of the CARRY benchmark and later re-enter CARRY by
pressing HOLD and then ZERO for 2 seconds without moving the Module.
You can preset the CARRY reference to any elevation such as at a survey-
ors benchmark using the ELEV function.
CARRY 22
Can measure the height of a mountain or locate
an elevation across town no pencil, paper or
calculator needed.
*Clear CARRY to zero
or set ELEVATION
(see ELEV) here.
Before Base Unit is moved to set-up 2, be sure to
hold’ Measurement Module securely in position
HOLD
Press
(Press 2 seconds to enter CARRY) once
Base Unit is secured at set-up 2
ZERO
Press
STEP 1
STEP 2
STEP 3
Set-up 1
Starting benchmark
Set-up 2
Set-up 3
BU
MM
BU
MM
MM
To clear
MARK
*Press 2 seconds
ZERO
CARRY

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Technidea ZIPLEVEL PRO-2000 and is the answer not in the manual?

Technidea ZIPLEVEL PRO-2000 Specifications

Ranges IconRanges
set-up vertical range40’ (12m)
set-up horizontal range200’ (60m)
carry function rangeNo limit
Accuracy IconAccuracy
reading repeatability0.1” (2mm) or 0.01” (0.2mm) HP
leveling accuracy0.1” (2mm) or 0.01” (0.2mm) HP
elevation accuracyGreater of 0.1” (2mm)/0.01” (0.2mm) HP or 0.2% reading <10’ (3m) & 0.35% reading >10’
Capacity IconCapacity
record capacity16, 384
record data capacity137 readings
settings/data retentionIndefinitely, even without battery
Operating Environment IconOperating Environment
operating temperature range-22°F to +158°F (-30C to +70C)
storage temperature range-40°F to +158°F (-40C to +70C)
shock resistanceMeasurement Module – 5’ (2m) drop on concrete
Battery IconBattery
battery type9V alkaline
battery life60 hours active use
auto shut-off time4 minutes inactive