The MARK function lets you create audible tones: 1) at a selected elevation,
2) for elevations within a selected band, or 3) elevations outside a selected
band. Tones may be set over ZIPLEVEL’s full vertical single setup range.
To set tones, place the Measurement Module at the desired elevation, press
MARK 2 seconds and hold steady until double band lines ash on the dis-
play then press MARK momentarily: 1) without moving the Module for a tone
at the elevation or 2) after moving the Module below for a tone within the
band or 3) after moving the Module above for a tone above the band, beeps
below and silence within. The fraction bar to the right ashes while in the
Mark function.
Press the MARK key 2 seconds to exit – settings will be lost. To exit and re-
tain settings, momentary press ON/OFF while pressing MARK. Press MARK
2 seconds to re-enter.
17 MARK MARK 18
Tones can supplement display to level or alarm
at height limits.
STEP 1
DISPLAY
TONES
TONE
AT
MARK
TONE
INSIDE
OF
BAND
TONE
OUTSIDE
OF
BAND
STEP 2
Enter at elevation Set band
Double beep Single beep
USE FOR PRECISE LEVELING
Mark Tone
USE FOR LESS
PRECISE LEVELING
Band
Band
Tone
No Tone
Steady
No Tone
Beeping Tone
FOR ROUGH LEVELLING OR
ELEVATION LIMIT INDICATION
MARK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Technidea ZIPLEVEL PRO-2000 and is the answer not in the manual?

Technidea ZIPLEVEL PRO-2000 Specifications

Ranges IconRanges
set-up vertical range40’ (12m)
set-up horizontal range200’ (60m)
carry function rangeNo limit
Accuracy IconAccuracy
reading repeatability0.1” (2mm) or 0.01” (0.2mm) HP
leveling accuracy0.1” (2mm) or 0.01” (0.2mm) HP
elevation accuracyGreater of 0.1” (2mm)/0.01” (0.2mm) HP or 0.2% reading <10’ (3m) & 0.35% reading >10’
Capacity IconCapacity
record capacity16, 384
record data capacity137 readings
settings/data retentionIndefinitely, even without battery
Operating Environment IconOperating Environment
operating temperature range-22°F to +158°F (-30C to +70C)
storage temperature range-40°F to +158°F (-40C to +70C)
shock resistanceMeasurement Module – 5’ (2m) drop on concrete
Battery IconBattery
battery type9V alkaline
battery life60 hours active use
auto shut-off time4 minutes inactive