P2002 Sierra
SECTION B
MAINTEN ANC E MAN UAL
pag.
B-19
2
st
Edition, April 22
th
, 2008
INSPECTION & SERVICING
13.2 PERIODIC INSPECTIONS
The first column in the following table describes the type of inspections to
be carried out “Nature of Inspection”; the second column, divided in three
parts, shows the “Inspection Intervals”. The symbol “marks the relative
inspection interval: 100 hours and the prospective interval for a special in-
spection.
Every porthole, fairing, panel etc. shall be removed to allow for inspection.
Procedures explained in SERVICING (Chap. 10) are included in the in-
spections.
Instructions for actions following inspection are detailed in specific sec-
tions pertaining to the aircraft group or system.
It is suitable to use TECNAM-prepared inspection checklists.
13.3 SERVICING REQUIREMENTS
N
ATURE OF INSPECTION
INSPECTION
I
NTERVALS
(
HRS
)
100
Special
ENGINE COMPARTMENT
1
Remove cowling and check for fuel, oil and coolant leaks; clean
engine compartment
2
Visually inspect electric pump connections
3
Visually inspect engine mount and silent-blocks attachments
4
Visually inspect exhaust manifold, muffler and heat exchanger
5
Visually inspect air intake and carburetor feed circuit
6
Visually inspect coolant reservoir, radiator and circuit line
7
Visually inspect oil reservoir, radiator and circuit line
8
Check wires and electrical connections (low and high tension)
9
Check carburetor control and throttle movement
10
Clean electric fuel pump filter
11
Check density of battery electrolyte
(a)
(a) Every 100h or more frequently in warm climate.