9. Error tracing and break down search
Error Cause Elimination
No suction power
(Smoke/gas are not sucked off).
Suction hose not attached at the
Mistral.
Attach the suction hose at the
Mistral.
Suction hose not attached at the
machine.
Attach the suction hose at the
industrial laser.
Damage of the suction hose. Exchange the suction hose.
Suction hose is attached to the
wrong machine.
Attach the suction hose to the
correct machine.
Suction hose is connected to the
wrong opening of the machine.
Attach the suction hose to the
correct opening of the machine.
No suction power and/or error
announcement „change filter“ with
a new filter-unit inserted.
Inlet clogs. Examine inlet. If necessary repair
disturbance.
Clean gas way clogs. Examine clean gas way. If
necessary repair disturbance.
Compressed-air hose kinked. Examine compressed-air hose. If
necessary repair disturbance.
Suction air way too long. Test the Mistral with a short length
of hose. If necessary, use only a
hose no longer than 2,5 m.
Suction power too small
(Smoke/gases are hardly sucked
off).
Filter-unit is full. Exchange filter-unit, deposit old
filter-unit duly!
Damage of the suction hose. Exchange the suction hose.
The suction hose is not attached
correctly at the machine.
Examine the fitting of the suction
hose on the machine, if necessary
attach the suction hose again.
The suction hose is not attached
correctly at the Mistral.
Examine the fitting of the suction
hose on the Mistral, if necessary
attach the suction hose again.
Clean gas way narrows. Examine clean gas way, if
necessary repair disturbance.
Suction hose is connected to the
wrong opening of the machine.
Attach the suction hose to the
correct opening of the machine.
Inlet narrows. Examine inlet, if necessary repair
disturbance.
Operating Instructions Mistral (Plus), Mistral Eco (Plus), Mistral Super Plus 110 and 230V vers. 4.10 Page 37 of 47