Commands Listed in Alphabetical Order
in the search. R
eturned values are 0, 1, or X (don’t care, which is the default).
SEARCH<x> is the search number, which is always 1, and B<x>
Conditions
This command requires a DPO4AERO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AERO application module for
MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MI L1553B:STATus:BIT:SRQ
{0|1|X|ZERo|ONE|NOCARE|OFF|ON}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MI L1553B:STATus:BIT:SRQ?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:CONDition
Examples
SEARCH:SEARCH1:TRIGger:A:BUS:B1:MIL155 3B:STATus:BIT:SRQ
NOCARE
sets the status word SRQ bit value to be used in the search to X.
SEARCH:SEARCH1:TRIGger:A:BUS:B1:MIL155 3B:STATus:BIT:SRQ?
might return 1.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SUBSF
When the MIL-STD-1553 bus search condition is set to ST ATus, this command
specifies the status word subsystem flag bit value (bit 17) to be used in the search.
Returned values are 0, 1, or X (don’t care, which is the default).
SEARCH<x> is
the search number, which is always 1, and
B<x>
Conditions
This command requires a DPO4AERO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AERO application module for
MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MI L1553B:STATus:BIT:
SUBSF { 0|1|X|ZERo|ONE|NOCARE|OFF|ON }
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MI L1553B:STATus:BIT:
SUBSF?
2-690 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual