Commands Listed in Alphabetical Order
Related Commands
SEARCH:SEARCH
<x>:TRIGger:A:BUS:B<x>:MIL1553B:CONDition
Arguments
0
1
X
sets the value to X (“don’t care”) which is the default.
ZERO sets the value to 0.
ONE sets the value to 1.
NOCARE sets the value to X (“don’t care”) which is the default.
OFF sets the value to 0.
ON sets the value to 1.
Examples
SEARCH:SEARCH1:TRIGger:A:BUS:B1:MIL155 3B:STATus:BIT:
SUBSF N OCARE
sets the status word subsystem flag bit value to be used in the
search to X.
SEARCH:SEARCH1:TRIGger:A:BUS:B1:MIL155 3B:STATus:BIT:
SUBSF?
might r
eturn 1.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF
When the MIL-STD-1553 bus search condition is set to STATus, this command
specifies the status word terminal flag bit value (bit 19) to be used in the search.
Returned values are 0, 1, or X (don’t care, which is the default).
SEARCH<x> is
the search number, which is always 1, and
B<x>
Conditions
This command requires a DPO4AERO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AERO application module for
MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MI L1553B:STATus:BIT:TF
{0|1|X|ZERo|ONE|NOCARE|OFF|ON}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MI L1553B:STATus:BIT:TF?
Related Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:MIL1553B:CONDition
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-691